gbGreat Britain (EN)
The maximum cable diameter strongly depends on the bending radius and the desired cable type. Please contact us.
t
[mm]
|
hi
[mm]
|
hG
[mm]
|
hG'
[mm]
|
Bk
[mm]
|
BEF
[mm]
|
qk
[kg/m]
|
---|---|---|---|---|---|---|
99.5 | 80 | 110 | 116.5 | Bi + 30 | Bi + 36 | 3.833 – 3.834 |
Bi
[mm]
| |||||||
---|---|---|---|---|---|---|---|
85 | 125 | 138 | 150 | 180 | 196 | 225 | 250 |
KR
[mm]
| ||||||
---|---|---|---|---|---|---|
150 | 210 | 250 | 300 | 350 | 400 | 500 |
UA1995
030
150
210
3582
VS
The divider system is mounted on every 2nd chain link as a standard. As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).
For applications with lateral acceleration and lying on the side, divider with arresting cams are available.
The locking cams click into place in the locking grids in the stays (version B).
Vers. |
aT min
[mm]
|
ax min
[mm]
|
ac min
[mm]
|
ax grid
[mm]
|
nT min |
---|---|---|---|---|---|
A | 10 | 16 | 12 | – | – |
B | 10 | 17.5 | 13.5 | 2.5 | – |
Number of dividers for design 020 depending on Bi
Vers. |
aT min
[mm]
|
ax min
[mm]
|
ac min
[mm]
|
ax grid
[mm]
|
nT min |
---|---|---|---|---|---|
A | 10 | 16 | 12 | – | 2 |
B | 10 | 17.5 | 13.5 | 2.5 | 2 |
* not for design 020
As a standard, the divider version A is used for vertical partitioning within the cable carrier. The complete divider system can be moved within the cross section.
Divider version A
End divider
Vers. |
aT min
[mm]
|
ax min
[mm]
|
ac min
[mm]
|
nT min |
---|---|---|---|---|
A | 8/4* | 14 | 10 | 2 |
Number of dividers for design 020 depending on Bi
* for End divider
The dividers are fixed by the partitions, the complete divider system is movable in the cross section.
ax (center distance of dividers) [mm] | ||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ac (nominal width of inner chamber) [mm] | ||||||||||||||||||||||||||||||||
14 10 | 16 12 | 19 15 | 23 19 | 24 20 | 28 24 | 29 25 | 32 28 | 33 29 | 34 30 | 38 34 | 39 35 | |||||||||||||||||||||
43 39 | 44 40 | 48 44 | 49 45 | 54 50 | 58 54 | 59 55 | 64 60 | 68 64 | 69 65 | 74 70 | 78 74 | |||||||||||||||||||||
79 75 | 80 76 | 84 80 | 88 84 | 89 85 | 94 90 | 96 92 | 99 95 | 112 108 |
An additional central support is required when using plastic partitions with ax > 49 mm.
TS3
A
3
K1
K4
34
38
VR1
VR3
Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).
If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.
The universal mounting brackets (UMB) are made from plastic and can be mounted from above, from below or on the face side.
Recommended tightening torque:
27 Nm for screws M8
F – fixed point
M – driver
U – universal mounting bracket
UMB
F
U
UMB
M
U
UMB
UMB
F
M
U
U
We recommend the use of strain reliefs at the driver and fixed point.
Reliable, robust with high availability. Your benefit from many years of experience combined with ongoing optimization, proven in tests and praxis. TRAXLINE® cables stand for competent system-supply with worldwide on-site service.
to TRAXLINE®From pre-assembled cables to complex, ready-to-connect systems, from lot size 1 to series – worldwide thousands of KABELSCHLEPP systems are reliably in use. The benefits of TOTALTRAX® systems are obvious: just one person of contact, one order number, delivery just-in-time to your production facility, shortest downtimes thanks to plug&play installation.
to TOTALTRAX®Reliable unrolling and optimum gliding for long travel lengths
to Support traysFor optimum placement with dynamic use of cables
to Strain relief devicesConfiguration guidelines:
The latest TSUBAKI KABELSCHLEPP information material: