to top Arrow Up

UA1555.030

Stay variant 030 – with outside opening and detachable crossbars

ua1555_030_start.png

Properties

  • Weight-optimised plastic frame with particularly high torsional rigidity.
  • Swivable and detachable left or right in any position.
  • Outside: openable and detachable.
test
Stay arrangement on every chain link

Stay arrangement on each chain link (VS: fully-stayed)

Inner width
Bi 50 – 150 mm

Dimensions

Dimensions
Important information

The maximum cable diameter strongly depends on the bending radius and the desired cable type.
Please contact us.

Calculating the cable carrier length
Cable carrier length LK: LK ≈ LS/2 + LB
Cable carrier length Lk rounded to pitch t
t
[mm]
hi
[mm]
hG
[mm]
hG'
[mm]
Bk
[mm]
BEF
[mm]
qk
[kg/m]
55.5385053Bi + 18Bi + 221.13 – 1.51
Bi
[mm]
5075100125150
KR
[mm]
6380100125160200
Order example
Order code

UA1555

030

125

160

1887

VS

Our technical support can provide help for gliding arrangements: technik@kabelschlepp.de

Inner distribution

Divider systems

The divider system is mounted on every 2nd chain link as a standard. As a standard, dividers or the complete divider system (dividers with height separations) are movable in the cross section (version A).

For applications with lateral acceleration and lying on the side, divider with arresting cams are available.
The locking cams click into place in the locking grids in the crossbars (version B).

Divider system TS0

without height separation
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A5107.5
B5107.52.5

Number of dividers for design 020 depending on Bi
Version B: not for design 020

Divider system TS0

Divider system TS1

with continuous height separation*
Vers.
aT min
[mm]
aT max
[mm]
ax min
[mm]
ac min
[mm]
ax grid
[mm]
nT min
A520107.52
B520.5107.52.52

* not for design 020

Divider system TS1

Divider system TS3

with height separation consisting of plastic section subdivisions
Vers.
aT min
[mm]
ax min
[mm]
ac min
[mm]
nT min
A515102

* not for design 020

The dividers are fixed with the partitions. The entire divider system can be moved in the cross section.

Divider system TS3
Divider system TS3
ax (center distance of dividers) [mm]
ac (nominal width of inner chamber) [mm]
15
10
20
15
25
20
30
25
35
30
40
35
45
40
55
50
65
60
75
70
Order example
Order code

TS3

A

2

K1

K4

34

38

VR1

VR3

Please state the designation of the divider system (TS0, TS1,...), version and number of dividers per cross section [nT ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [aT/ax] (as seen from the driver).

If using divider systems with height separation (TS1 – TS3), please also state the positions [e.g. VD23] viewed from the left driver belt. You are welcome to add a sketch to your order.

End connectors

UA1555 End Connector UMB
UA1555 End Connector UMB
Important information

Recommended tightening torque: 
5 Nm for screws M5 - 8.8

Bi
[mm]
nz
50
2 x 3
75
2 x 5
90
2 x 6
100
2 x 7
125
2 x 9
150
2 x 11
UA1555 End Connector UMB
UA1555 End Connector UMB
Connection point

F – fixed point
M – driver

Connection type

U – universal mounting bracket

Order example
Order code

UMB

F

U

UMB

M

U

End connector

UMB

UMB

Connection point

F

M

Connection type

U

U

Important information

We recommend the use of strain reliefs at the driver and fixed point.

UA1555 End Connector
UA1555 End Connector
Important information

Recommended tightening torque: 
6 Nm for screws M6 - 8.8

Bi
[mm]
nz
50
2 x 4
75
2 x 6
100
2 x 8
125
2 x 10
150
2 x 12
UA1555 End Connector
UA1555 End Connector
Connection point

F – fixed point
M – driver

Connection type

A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint, rotated 90° to the outside
K – threaded joint, rotated 90° to the inside

Order example
Order code

End connector

F

A

End connector

M

A

End connector

End connector

End connector

Connection point

F

M

Connection type

A

A

UA1555 End Connector long – plastic
UA1555 End Connector long – plastic
Important information

Recommended tightening torque: 
6 Nm for screws M6 - 8.8

Bi
[mm]
nz
50
2 x 4
75
2 x 6
100
2 x 8
125
2 x 10
150
2 x 12
UA1555 End Connector long – plastic
UA1555 End Connector long – plastic
Connection type

F – fixed point
M – driver

Connection surface

A – threaded joint outside (standard)
I – threaded joint inside
H – threaded joint, rotated 90° to the outside
K – threaded joint, rotated 90° to the inside

Order example
Order code

End connector U0555

F

A

End connector U0555

M

A

End connector

End connector U0555

End connector U0555

Connection point

F

M

Connection type

A

A

Downloads

Matching with

Cables for cable carriers – TRAXLINE®

Reliable, robust with high availability. Your benefit from many years of experience combined with ongoing optimization, proven in tests and praxis. TRAXLINE® cables stand for competent system-supply with worldwide on-site service.

to TRAXLINE®

Ready-to-connect cable carrier systems – TOTALTRAX®

From pre-assembled cables to complex, ready-to-connect systems, from lot size 1 to series – worldwide thousands of KABELSCHLEPP systems are reliably in use. The benefits of TOTALTRAX® systems are obvious: just one person of contact, one order number, delivery just-in-time to your production facility, shortest downtimes thanks to plug&play installation.

to TOTALTRAX®

Accessories

Reliable unrolling and optimum gliding for long travel lengths

to Support trays
to Guide channels

For optimum placement with dynamic use of cables

to Strain relief devices

Services

Product Configurator
Product Configurator
Close

Product Configurator

  • Efficient, quick and complete configuration ­ the result is your individual product with an excellent price-performance ratio
  • Product configurator OnlineEngineer + suitable CAD model from CADenas without having to exit the portal
CADenas
CADenas
Close

CADenas

  • Decrease your engineering times
  • Accelerate your design processes
  • Configure with original data directly from the manufacturer
  • Providing 3D component models in a variety of CAD formats
Glossary
Glossary
Close

Glossary

Cable Carriers – Overview of general abbreviations and pictographs

Technical information
Technical information
Close

Technical information

Configuration guidelines:

  • Selecting a suitable cable carrier
  • Placement guidelines for cables and hoses
  • Installation variants
Literature
Literature
Close

Literature

The latest TSUBAKI KABELSCHLEPP information material:

Subject to change.
Contact
Please contact us:
Your contact: